1 Introduction
20
1
Flow straightener
2
Sensor sleeve
3
O-ring
4
Counter
5
Clamp screw
6
Thermowell for
temperature comparison (fiscal)
There is a permanent magnet on the end disc of the turbine shaft which induces a
voltage pulse in the Wiegand sensor with every rotation. This pulse is supplied to the
measuring unit of the meter head, which detects the operating volume flow directly as
a main totalizer and determines the gas volume flowing through the meter by adding
up the pulses and division by the meter factor (number of pulses per m
ating volume is shown in the display of the TME400.
Manual TME400-VMF · EN02 · 2018 September 6th
Figure 1: Turbine meter sectional drawing
7 Sensor
8 Permanent magnet
9 Pressure connection
10 Turbine wheel
11 Oil pump
). This oper-