RMG TME400-VMF Operating Manual page 69

Turbine meter
Hide thumbs Also See for TME400-VMF:
Table of Contents

Advertisement

Z05
X:Y maximum pulse
Z10
Error register 1
Z11
Error register 2
Z12
Status register 1
Z13
Status register 2
Z15
Code word release
Z16
Change code word
Z17
Device type
Z24
Display active max.
Z25
Volume metering mode
Z26
Characteristic correc-
tion
see above
Display value
Display value
Display value
Display value
Note
The code word for the TME400 is:
With entry of this code word, the protected parameters can be
changed.
A new password can be defined here.
0
TME400-VM (default)
1
TME400-VC
2
TME400-VM MID
3
TME400-VC MID
0
1 minute (default)
1
5 minutes
2
60 minute test
The time during which the display is active for tests is selected as
60 minutes. In general, however, it must be observed that higher
energy consumption is associated with this time, so this time should
be selected as short as possible, if possible.
0
1-channel without errors (default)
1
1-channel stop on error
2
1-channel run on error
3
1-channel start / stop
4
1-channel reset
5
2-channel stop on error
6
2-channel run on error
7
2-channel without X:Y error
With 1-channel measurements (0, 1, 2, 3, 4), the Z04 and Z05 pulse
comparison is not activated.
An entry for sensor type 2 is superfluous and has no further signifi-
cance.
If the TME400 is supplied with a current supply, the TME400 ena-
bles a characteristic correction via a polynomial. This correction
must be activated with coordinate Z26. With this polynomial correc-
tion, the corresponding percentage deviations of the turbine meter
1 2 3 4
Manual TME400-VMF · EN02 · 2018 September 6th
4 Operation
63