1.3. Overview of versions
Description
1.3.1.
The TME400-VM is a turbine meter which is used for volume measurement of the
operating volume of non-aggressive gases and burnable gas. The operating volume
flow is determined based on the turbine speed, which is scanned by means of a Wie-
gand or Reed sensor element and then added together in internal archives. The re-
sult is registered in an electronic meter.
There are a high-frequency (HF) and a low-frequency (LF) output, where the HF out-
put is preferably used as a flow sensor for control tasks and remote transmission. In
addition to these outputs, the TME400 VM has a serial RS 485 interface for digital
data readings and parameterization. The TME400-VM is used in non-custody-
transfer applications.
The TME400-VMF (MID) is the turbine meter for custody-transfer applications and
has an equivalent function and operating method to the TME400-VM. The essential
difference is the 2-channel measuring head version. It is used in custody-transfer
applications.
Device features
1.3.2.
TME400-VM
•
Non-custody-transfer measurements
•
Electronic meter
•
Alarm output
•
Optionally available in a version with remote meter
(max. distance from meter head to meter of 15 m;
see chapter 5.1.2.1 Pulse In measuring inputs (sensor 1 / 2))
•
2x pulse inputs selectable for Reed, Wiegand and external pulse transmitters
(remote meters)
•
1x contact input
•
1x HF output
(input pulse of pulse input 1 is output with defined pulse width of 1 ms)
•
1x LF output with defined pulse width (20 ms, 125 ms or 250 ms)
•
1x RS485 with external power supply
•
1x optional power module
•
Power supply via 3.6V lithium cell or an external power supply which is assigned
to the RS485 interface (supply via power module alone is not adequate and a
battery is required for support)
•
Archive memory for events, parameters, measurements