Pressure Loss - RMG TME400-VM VMF Series Operating Manual

Turbine meter
Hide thumbs Also See for TME400-VM VMF Series:
Table of Contents

Advertisement

300
200
4000
325
6500
400
325
6500
500
10000
500
500
10000
800
16000
600
800
16000
1250
25000

Pressure loss

1.4.2.10.
The measuring parts for determining pressure loss are 1 x DN upstream and down-
stream of the meter. The pressure loss is calculated according to the following for-
mula:
Dp
where:
pressure loss
Z
coefficient of pressure loss
p
r
density
Q
volume flow rate at measurement conditions [m³/h]
m
DN nominal diameter
Device type
Turbine meter TME400
Perforated plate straightener L1 according to ISO/DIN
Perforated plate straightener L2 according to ISO/DIN
Perforated plate straightener L3 according to ISO/DIN
Perforated plate straightener LP-35 RMG standard
Bend straightener RB 19 according to ISO/DIN
The values for Z
are rough averages. The exact value is calculated from the pres-
p
sure loss, which is determined when testing the meter.
1:20
2
1:20
2
1:20
2
1:20
2
1:20
2
1:20
2
1:20
2
1:20
2
2
Q
D
=
×
× r
p
Z
m
p
4
DN
Manual TME400-VMF · EN07 · December, 7
1 Introduction
1
1
1
1
1
1
1
1
[mbar]
[-]
[kg/m³]
[mm]
Z
p
5040
3150
6300
9450
1260
1260
th
2020
33