5 Technical data
5.1.6.
Note
To avoid measuring errors due to electromagnetic interference, the meter
housing must be grounded with the ground connection on the right section
72
of the housing (see Figure 15: Grounding the meter).
Minimum cable cross-section:
• length of up to 10 m:
• length of 10 m or higher: 10 mm²
In the process, a conductive connection between the TME400 and the pipeline must
be provided as shown in the figure below.
Manual TME400-VMF · EN02 · 2018 September 6th

Ground

Figure 15: Grounding the meter
6 mm²