4 Operation

4.3. Equations in the TME400

The TME400 enables calculation of different values from the measured data and in
the data entered in the TME400. For a better understanding, some variables and
formula in this chapter are presented in advance; other equations and definitions of
parameters are found in the chapter 4.3.3. Coordinates in context.
54
4.3.1.
Formula symbol Units
q
m
f
V
K
V
V
m
P
V
K
Z1
K
Z2
4.3.2.
Variables presented from the previous chapter can be used for the basic equation for
the volume flow at measurement conditions:
Manual TME400-VMF · EN02 · 2018 September 6th

Variable description

m
3
/h
Hz
I/m
3
m
3
Nondimensional (1)
m
3
/I
3
m
/I

Standard formula

(Volume flow at measurement conditions =
Name
Operating volume flow at
measurement condition
Frequency of the volume transmitter
Meter factor
Operating volume flow rate at
measurement condition
Volume pulse
Meter factor (only for output contacts)
Meter factor (only for output contacts)
��
1
��
��
=
��
��
��
��
��1
������������ ���� ������������
Meter factor �� ��otalizer factor
)