RMG TME400-VMF Operating Manual page 29

Turbine meter
Hide thumbs Also See for TME400-VMF:
Table of Contents

Advertisement

DN
d1
50
2"
51
80
3"
81
100
4"
106.4
150
6"
157.2
200
8"
215.9
250
10"
268.3
300
12"
317.5
400
16"
400
500
20"
500
600
24"
603.3
Note
When flange seals which protrude into the pipeline are used for turbine me-
ters, the measuring accuracy can be influenced negatively. Ensure that the
flange seals do not protrude beyond the seal surfaces into the pipeline.
Danger
Gas escape due to incorrect seal
If incorrect flange seals are used for the assembly of turbines, an explosive
gas mixture can form due to leaks.
Danger of poisoning and explosion!
In addition, the stress on the flange is increased to an impermissible level
when tightening the thread bolts.
Ensure secure fastening/attachment of the TME400 during assembly in order
to avoid crushing. Ensure that you keep your fingers (or other body parts)
away from these openings and gaps when pulling the flanges together.
ANSI 300
d2
d3
d1
69.9
85.9
54
101.6
120.7
86
127.0
149.4
108
182.6
209.6
162
233.4
263.7
213
287.3
317.5
267
339.9
374.7
318
422.4
463.6
414
525.5
577.9
518
628.7
685.8
618
PN 64
d2
d3
66
84
51
95
119
81
120
144
106.4
174
200
157.2
225
257
215.9
279
315
268.3
330
366
317.5
426
466
400
530
574
500
630
674
603.3
Manual TME400-VMF · EN02 · 2018 September 6th
1 Introduction
ANSI 600
d1
d2
69.9
85.9
101.6
120.7
120.7
149.4
23
174.8
209.6
225.6
263.7
274.6
317.5
327.2
374.7
412.8
463.6
520.7
577.9
628.7
685.8