Measuring Ranges; Measuring Accuracy - RMG TME400-VMF Operating Manual

Turbine meter
Hide thumbs Also See for TME400-VMF:
Table of Contents

Advertisement

1 Introduction
1.4.2.8.
Type TME400 turbine meters have measuring ranges of at least 1:20 at atmospheric
pressure (see chapter 1.4.2.9 Measuring accuracy). At a higher pressure, the meas-
uring range can be expanded to 1:50. The measuring ranges are between 2.5 and
25,000 m
30
1.4.2.9.
The following error limits apply within the permissible measuring range:
DN
Qmin
[m³/h]
25
40
80
50
80
100
80
100
Note
With a slightly smaller measuring range of 1:16, turbine meters are also
available in nominal diameters DN 80 and DN 100, which have an increased
accuracy with a deviation of max. ±1% in the range of 0.2 x Q
150
200
250
Manual TME400-VMF · EN02 · 2018 September 6th

Measuring ranges

/h (operating conditions), depending on meter size.
3

Measuring accuracy

Qmax
MR
[m³/h]
2.5
25
1:10
6
70
1:12
13
160
1:12
6
100
1:16
16
250
1:16
25
400
1:16
25
400
1:16
40
650
1:16
13
250
1:20
20
400
1:20
20
400
1:20
32
650
1:20
32
650
1:20
50
1000
1:20
80
1600
1:20
80
1600
1:20
125
2500
1:20
125
2500
1:20
Measurement deviation in the range of
Qmin-0,2 x Qmax
[%]
3
3
3
3
3
3
2
2
3
3
3
3
2
2
2
2
2
2
0,2 x Qmax-Qmax
[%]
2
1.5
1.0
1.5
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
-Q
.
max
max
1
1
1
1
1
1