1 Introduction
1.3. Overview of versions
1.3.1.
The TME400-VM is a turbine meter which is used for volume measurement of the op-
erating volume of non-aggressive gases and burnable gas. The operating volume
16
flow is determined based on the turbine speed, which is scanned by means of a Wie-
gand or Reed sensor element and then added together in internal archives. The re-
sult is registered in an electronic meter.
There are a high-frequency (HF) and a low-frequency (LF) output, where the HF out-
put is preferably used as a flow sensor for control tasks and remote transmission. In
addition to these outputs, the TME400 VM has a serial RS 485 interface for digital
data readings and parameterization. The TME400-VM is used in non-custody-trans-
fer applications.
The TME400-VMF (MID) is the turbine meter for custody-transfer applications and
has an equivalent function and operating method to the TME400-VM. The essential
difference is the 2-channel measuring head version. It is used in custody-transfer
applications.
1.3.2.
TME400-VM
•
Non-custody-transfer measurements
•
Electronic meter
•
Alarm output
•
Optionally available in a version with remote meter
(distance from meter head to meter: 10 m;
see appendix C
•
2x pulse inputs selectable for Reed, Wiegand and external pulse transmitters
(remote meters)
•
1x contact input
•
1x HF output
(input pulse of pulse input 1 is output with defined pulse width of 1 ms)
•
1x LF output with defined pulse width (20 ms, 125 ms or 250 ms)
•
1x RS485 with external power supply
•
1x optional power module
•
Power supply via 3.6V lithium cell or an external power supply which is assigned
to the RS485 interface (supply via power module alone is not adequate and a
battery is required for support)
•
Archive memory for events, parameters, measurements
Manual TME400-VMF · EN07 · December, 7
Description
Device features
Dimensions)
th
2020