NEC Express5800/R120h-2M Maintenance Manual page 34

Nec express server. express5800 series
Hide thumbs Also See for Express5800/R120h-2M:
Table of Contents

Advertisement

Chapter 1 Maintenance
If the controller is physically damaged, replace it.
If the controller is recognized by the system ROM, then reseat the controller.
Run controller diagnostics and follow the steps displayed.
Update the firmware.
Download the Active Health System log.
[?]
Controllers are no longer redundant (the controller shows errors during the POST process, or the cache is
disabled)
Make sure that the controllers are supported for the server.
Make sure the controllers are installed and seated properly.
Make sure that the cables are properly connected.
If the controller is physically damaged, replace it.
Run controller diagnostics and follow the steps displayed.
Make sure that the controllers are compatible controller models.
Verify that the controller cache sizes are compatible.
Verify that the FBU (flash backup unit) is installed and connected correctly.
Update the firmware.
Download the Active Health System log.
[?]
Smart Array S100i SR Gen10 SW RAID drives are not found when RAID mode is disabled
When Smart Array S100i SR Gen10 SW RAID controller is enabled on a server and RAID mode is
disabled in the System Utility, then the drives are listed as AHCI drives or H220i drives and the RAID
controller is not found in POST or device manager. When RAID mode is enabled, the drives appear as
Smart Array S100i SR Gen10 SW RAID controller drives.
Below is the procedure to correct the problem.
1. Press the <F9> key during the startup process to access System Utility.
2. In the System Configuration menu, select BIOS/Platform Configuration (RBSU) → Storage
Options → SATA Controller Options → Embedded SATA Configuration → Smart Array SW
RAID Support.
3. Press <F10> key to save the configuration.
4. Reboot the server.
[?]
Data located on drives accessed in RAID mode is not compatible with data accessed from non-RAID mode
Recommends that you access drive data only when the same RAID or non-RAID mode is enabled. Back
up and restore the data on the drives.
[?]
The Smart Array controller does not show logical drives after moving drives to a new server or JBOD
Be sure to follow all drive roaming rules when migrating drives.
34
Express5800/R120h-1M, R120h-2M Maintenance Guide
5. Troubleshooting