NEC Express5800/R120h-2M Maintenance Manual page 197

Nec express server. express5800 series
Hide thumbs Also See for Express5800/R120h-2M:
Table of Contents

Advertisement

Chapter 3 Appendix
Class
Error code
Slot %1 Smart Array - More devices
UEFI
1922
attached than this controller supports.
Some devices are ignored.
Slot %1 Smart Array - Valid data found
in write-back Cache. Data will
UEFI
1930
automatically be written to the logical
drive(s).
Slot %1 Smart Array - Data in
UEFI
1931
write-back cache has been lost.
Slot %1 Smart Array - Write-back
UEFI
1932
cache configuration error. %2
Slot %1 Smart Array - Consecutive
power loss during I/O transactions on
UEFI
1933
non-optimal write-back volumes. This
might have resulted in data integrity
issues.
Slot %1 Smart Array - Battery is not
UEFI
1934
present. Caching is disabled.
Slot %1 Smart Array - Battery is
UEFI
1935
charging. Caching will be enabled once
the battery has been charged.
Slot %1 Smart Array - Cache Module
UEFI
1936
Self-Test Error Occurred. %2
Slot %1 Smart Array - Battery is
UEFI
1937
present but the controller battery cable
is not attached.
Slot %1 Smart Array - The following
UEFI
1940
logical drives are failed: %2.
Error message
Express5800/R120h-1M, R120h-2M Maintenance Guide
Action
Please take actions in the following order.
1. Updating the firmware of the Slot% 1 controller
to the latest version may solve the error. Refer to
the release notes to check if there are related
improvements. If there are related improvements,
update the firmware of the Slot% 1 controller.
2. Reduce the number of hard disk drives
connected to the Slot% 1 controller.
Although the power has been turned off with the
data still in the write-back cache, the data was
automatically written to the logical drive. If the
data is not recorded repeatedly, no action is
required.
To prevent data from remaining in the write-back
cache, perform a normal shutdown of the system.
If the problem persists, contact your sales
representative.
Perform the following measures
1. Check the integrity of the data stored in the
drive.
2. To prevent data from remaining in the
write-back cache, perform a normal shutdown of
the system.
3. If the data is missing, restore the previous
backup data.
Take either of the following steps.
1. Change the drive array configuration back to
what matches the cache.
2. Clear the data in the cache by executing the
storage software.
Please take actions in following order.
1. Make sure the controller (card) in slot %1 to be
installed.
2. Make sure the power supply and the batteries
have no problem.
Install the cache module battery.
Action is not necessary.
Contact your sales representative.
Make sure the battery cable for the controller is
properly connected.
Make sure the cable is properly connected to the
connector.
If the problem persists, contact your sales
representative.
Contact your sales representative.