Chapter 3 Appendix
Class
Error code
Power Fault Detected - Embedded
UEFI
226
Storage Controller %1.
UEFI
227
Power Fault Detected - M.2 riser
IMPORTANT: The device in PCIe
Slot %1 is SRIOV capable but is
UEFI
244
installed in a slot that does NOT support
SRIOV.
IMPORTANT: Switches SW1 and SW3
UEFI
251
are ON. This is only used to recover %1
functionality.
IMPORTANT: One or more embedded
PCIe Device(s) are attached to a
UEFI
253
non-installed processor and will not
function.
IMPORTANT: The PCIe Device installed
in Slot %1 has no corresponding
UEFI
254
processor installed and will not
function.
Server Platform Services Firmware
UEFI
261
requires update.
Server Platform Services Firmware in
Recovery Mode. SPS Firmware
UEFI
264
Update Switch 12 of the Maintenance
Switch is in the ON position.
Non-Volatile Memory Corruption
Detected. Configuration settings
UEFI
266
restored to defaults. If enabled, Secure
Boot security settings may be lost.
IMPORTANT: Default configuration
UEFI
267
settings have been restored at the
request of the user.
Error message
Express5800/R120h-1M, R120h-2M Maintenance Guide
Action
Turn off the power on the unit, disconnect the
power cord, and check the installation of internal
storage controller %1. Wait 30 seconds, and then
restart it. If the problem persists, contact your
sales representative.
Turn off the power on the unit, disconnect the
power cord, and check the installation of M.2 riser.
Wait 30 seconds, and then restart it. If the problem
persists, contact your sales representative.
When using the SRIOV, install an optional card in
the slot where the SRIOV is supported. If the
problem persists, contact your sales
representative.
Set the maintenance switch to OFF unless the
setting is specified in the operating procedure etc.
When operating the maintenance switch, follow the
procedure in Chapter 1 (7. Resetting and Clearing
the Server) in this manual.
If the problem persists, contact your sales
representative.
Some built-in devices are not available unless the
processor is added. Add a processor if necessary. If
the problem persists, contact your sales
representative.
The optional card is connected to a PCIe slot that is
not available unless a processor is added. Change
the slot which the PCIe expansion card is
connected to, otherwise add a processor. If the
problem persists, contact your sales
representative.
Update the server platform service firmware. If the
problem persists, contact your sales
representative.
Set the maintenance switch SW12 to OFF unless
the setting is specified in the operating procedure
etc.
When operating the maintenance switch, follow the
procedure in Chapter 1 (7. Resetting and Clearing
the Server) in this manual.
If the problem persists, contact your sales
representative.
The system configuration has been initialized to
default. Make the necessary settings in the system
utility. If the problem persists, contact your sales
representative.
The system configuration has been initialized to
default. Make the necessary settings in the system
utility. If the problem persists, contact your sales
representative.