Chapter 3 Appendix
Class
Error code
Slot %1 Error - Failure to apply Virtual
UEFI
2409
Connect (VC) settings.
Slot %1 Error - Controller I/O timeout
UEFI
2410
failure.
%1: iSCSI Error - Failed to acquire
UEFI
2411
DHCP client network address.
%1: iSCSI Error - Failed to acquire
UEFI
2412
DHCP target network address.
%1: iSCSI Error - Failed to acquire
UEFI
2413
DHCP iSNS Server IP address.
UEFI
2414
%1: iSCSI Error - iSCSI login failed.
%1: iSCSI Error - Boot LUN not
UEFI
2415
available.
%1: Error - Controller firmware not
UEFI
2416
ready.
%1 %2 Error - Rx/Tx is disabled on this
UEFI
2419
device because an unsupported SFP+
or QSFP module type was detected.
%1 %2 Error - The UEFI driver for the
UEFI
2420
device detected an older version of the
NVM image than expected.
%1 %2 Error - The UEFI driver for the
UEFI
2421
device detected a newer version of the
NVM image than expected.
%1 %2 Error - The UEFI driver for the
UEFI
2422
device stopped because the NVM image
is newer than expected.
Trusted Platform Module (TPM) was
UEFI
3100
successfully bound to system.
Unbound Trusted Platform Module
UEFI
3101
(TPM) detected.
A Critical Error Event that has kept the
UEFI
120
system from booting. -System Halted!
UEFI
163
Time & Date Not Set.
Unsupported DIMM Configuration
Detected - Installed DIMM
configuration does NOT support
UEFI
209
configured AMP Mode. System will
operate in Advanced ECC Mode. (Major
Code:%1 Minor Code:%2).
Error message
Express5800/R120h-1M, R120h-2M Maintenance Guide
Action
Confirm the VC configuration. Apply the VC
configuration again after restarting the server.
Restart the unit. If the problem persists, contact
your sales representative.
Check the network cables and the DHCP server
configuration. Restart the server.
Check the network cables and the DHCP server
configuration. Restart the server.
Check the network cables, the DHCP server
configuration and the iSNS server configuration.
Restart the server.
Confirm and set the cable connection, the
controller configuration, and the configurations of
iSCSI initiator and the target properly. Then restart
the server.
Confirm and set the controller configuration and
the iSCSI server configuration properly. Then
restart the server.
Restart the unit. If the problem continues, update
FW. If the problem persists, contact your sales
representative.
Contact your sales representative.
Update the NVM image. If the problem persists,
contact your sales representative.
Update the NVM UEFI driver to the latest version. If
the problem persists, contact your sales
representative.
Update the NVM UEFI driver to the latest version. If
the problem persists, contact your sales
representative.
Action is not necessary. The unit restarts
automatically.
Action is not necessary. The TPM is integrated into
the unit after being cleared.
Contact your sales representative.
Set the date and time of the server.
For the details of the DIMM configuration required
to use the AMP mode, refer to the User's Guide.
If the problem persists, contact your sales
representative.
1. IML Error Message
201