Chapter 3 Appendix
Class
Error code
Scalable Persistent Memory backup
UEFI
433
device failure on Box %1 Bay %2.
Persistent data may have been lost.
Scalable Persistent Memory
configuration data on backup device
UEFI
434
Box %1 Bay %2 is invalid. Persistent
data may be lost.
Scalable Persistent Memory backup
UEFI
435
device on Box %1 Bay %2 is missing.
Scalable Persistent Memory backup
media write error on %1 Logical
UEFI
437
NVDIMM %2. Persistent data may have
been lost.
Scalable Persistent Memory backup
media read error on %1 Logical
UEFI
438
NVDIMM %2. Persistent data may have
been lost.
New Scalable Persistent Memory
UEFI
439
configuration rejected. System has
reverted to the previous configuration.
Persistent Memory Address Range
UEFI
440
Scrub has detected an error at
0x%1'%2.
NVDIMM Configuration Error - Scalable
Persistent Memory functionality is not
supported when NVDIMM-N is present
UEFI
441
in the system. Scalable Persistent
Memory functionality has been
disabled.
Scalable Persistent Memory backup
UEFI
442
media write error on Box %1 Bay %2.
Persistent data may have been lost.
Scalable Persistent Memory backup
UEFI
443
media read error on Box %1 Bay %2.
Persistent data may have been lost.
Scalable Persistent Memory arming
error on %1, Logical NVDIMM %2.
UEFI
444
The Logical NVDIMM could not be
armed and future backups are not
possible.
Scalable Persistent Memory backup
UEFI
445
device error on Box %1 Bay %2.
192
Error message
Express5800/R120h-1M, R120h-2M Maintenance Guide
Action
Please take actions in following order.
1. Back up the contents recorded in the persistent
memory to other media to protect the data.
2. Contact your sales representative.
Reinitialize the backup device of Box %1, Bay %2.
If the problem persists, contact your sales
representative.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Review the setting of the persistent memory.
If the problem persists, contact your sales
representative.
Contact your sales representative.
When using the persistent memory, remove the
NVDIMM-N from the server.
If the problem persists, contact your sales
representative.
Contact your sales representative.
Contact your sales representative.
Back up the contents recorded in the non-volatile
memory of the NVDIMM to other media. Contact
your sales representative.
Contact your sales representative.