NEC Express5800/R120h-2M Maintenance Manual page 186

Nec express server. express5800 series
Hide thumbs Also See for Express5800/R120h-2M:
Table of Contents

Advertisement

Chapter 3 Appendix
Class
Error code
NVDIMM Error - Uncorrectable Memory
Error - Processor %1, DIMM %2
UEFI
342
(SN:%3-%4-%5-%6). This NVDIMM
will not be available to the operating
system and data may have been lost.
IMPORTANT: NVDIMM backup power
has been lost and a future backup is not
possible. Data from the last successful
UEFI
343
backup is intact, but data modified after
the last successful backup will be lost if
power cannot be restored.
NVDIMM Error - NVDIMM Controller
Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6). An error was
found with the NVDIMM controller. The
UEFI
344
OS will not use the NVDIMM. Data from
last successful backup is still available,
but will be lost if controller error
persists.
NVDIMM Error - Erase Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM could
UEFI
345
not be erased by the NVDIMM
controller FW and future backups are
not possible.
NVDIMM Error - Arming Error -
Processor %1, DIMM %2
UEFI
346
(SN:%3-%4-%5-%6). NVDIMM could
not be armed and future backups are
not possible.
IMPORTANT: %1 is not charged
sufficiently to support the
energy-backed persistent memory
UEFI
351
installed in the system. The system will
wait for the battery to charge
sufficiently before continuing boot.
IMPORTANT: %1 is not charged
sufficiently to support the
energy-backed persistent memory
UEFI
352
installed in the system. System
configured to not wait for battery to
charge. Persistent memory regions
may not be available in the OS.
IMPORTANT: Possible Password
Corruption. The PW authentication
UEFI
353
algorithm detected an issue which has
been corrected.
186
Error message
Express5800/R120h-1M, R120h-2M Maintenance Guide
Action
Contact your sales representative.
Check the backup power supply of the NVDIMM.
Back up the contents recorded in the NVDIMM to
other media to protect the data. If the problem
persists, contact your sales representative.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
Perform one of the following actions.
1. Wait until the battery is fully charged so that the
unit can continue to be operated.
2. Press the <ESC> key to continue operating
without waiting for the battery fully charged.
Perform one of the following actions.
1. Wait until the battery is fully charged so that the
unit can continue to be operated.
2. Change to the setting where the unit operation is
suspended until the battery is fully charged.
Reset your password. To clear the currently set
password, follow the procedure in Chapter 1 (7.
Resetting and Clearing the Server) in this manual.
If the problem persists, contact your sales
representative.
1. IML Error Message

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/r120h-1mExp810Exp807

Table of Contents