Chapter 3 Appendix
i40ei
27
When installing an OS
Microsoft-Windows-
Kernel-PnP
219
When starting system or connecting a
disk
Kernel-PnP
225
When applying Starter Pack
Service Control
Manager
7023
When running an OS for the first time
Service Control
Manager
7023
When running an OS for the first time or
rebooting it, or while the system is in use
Service Control
Manager
7030
When running an OS for the first time
Microsoft-Windows
-DistributedCOM
10010
When running an OS for the first time or
rebooting it
Microsoft-Windows
-NDIS
10317
When removing a team
216
The description for Event ID 27 from source "i40ei" cannot be found.
Either the component that raises this event is not installed on your local
Warning
computer or the installation is corrupted. You can install or repair the
component on the local computer.
This event does not affect system operation.
The driver \Driver\WudfRd failed to load for the device
Warning
xxxxxxxxxxxxxxxxxx.
This may be recorded when starting the system or connecting a disk
depending on timing, but does not affect system operation.
The application YYY with process id XXX stopped the removal or
ejection for the device ZZZ.
Warning
* ZZZ : Instance name of the device
YYY : Name of the process that was using the device
XXX : ID of the process that was using the device
This event does not affect system operation if it is logged when applying
Starter Pack.
"xxxxxxxx service terminated with the following error:
Error
A device attached to the system is not functioning."
This event does not affect system operation if it is recorded only on the
first startup and not recorded repeatedly.
The Data Sharing Service service terminated with the following
error: %%3239247874
* The description for Event ID 7023 from source Service Control
Manager cannot be found. Either the component that raises this event is
not installed on your local computer or the installation is corrupted. You
can install or repair the component on the local computer.
Error
If the event originated on another computer, the display information had
to be saved with the event.
The following information was included with the event:
Data Sharing Service
%%3239247874
The locale specific resource for the desired message is not present.
This event does not affect system operation.
The Printer Extensions and Notifications service is marked as an
Error
interactive service. However, the system is configured to not allow
interactive services. This service may not function properly.
This event does not affect system operation if it is recorded only on the
first startup and not recorded repeatedly.
The server {XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX} did not
Error
register with DCOM within the required timeout.
Refer to the following website.
http://support.microsoft.com/kb/956479/
Miniport Microsoft Network Adapter Multiplexor Driver,
{xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx}, had event Network Interface
Error
deleted while PNP Device still exists. Note that this event is provided for
informational purpose and might not be an error always (Eg: In case of
vSwitch which was recently un-installed or a LBFO team was removed)
This event does not affect system operation.