Chapter 3 Appendix
Class
Error code
IMPORTANT: The removal of a storage
device has been detected. The device
UEFI
286
has been removed from the Boot
Controller Order.
IMPORTANT: The removal of a network
device has been detected. The device
UEFI
287
has been removed from the Standard
Boot Order (IPL)
IMPORTANT: A new storage device has
UEFI
288
been detected and has been added to
the end of the Boot Controller Order.
A new network or storage device has
been detected. This device will not be
UEFI
289
shown in the Legacy BIOS Boot Order
options in RBSU until the system has
booted once.
IMPORTANT: The Standard Boot Order
(IPL) has been detected as corrupted
UEFI
291
and has been restored to default
values.
Invalid %1 Software RAID
Configuration. %2 SW RAID Mode is
UEFI
292
NOT supported when the Boot Mode is
configured for legacy BIOS Mode.
IMPORTANT: iLO Security is disabled by
the associated switch being set to the
UEFI
297
ON position. Platform security is
DISABLED.
%1 Configuration Error - The system
UEFI
311
has exceeded the installed battery
capacity.
%1 %2 Failure - Communication with
UEFI
312
the battery failed. Its output may not
be enabled.
%1 %2 Failure - Battery Shutdown
UEFI
313
Event Code: 0x%3.
An uncorrectable memory error was
UEFI
315
detected prior to this system boot.
An Unexpected Shutdown was detected
UEFI
319
prior to this boot.
Enclosure Power Event detected. Boot
UEFI
320
delayed until condition is resolved.
Error message
Express5800/R120h-1M, R120h-2M Maintenance Guide
Action
Action is not necessary.
Action is not necessary.
Action is not necessary.
Action is not necessary.
Action is not necessary.
When using the corresponding Software RAID, the
boot mode must be changed to the UEFI mode. If
the problem persists, contact your sales
representative.
The maintenance switch SW1 should be set to OFF
unless the setting is specified in the operating
procedure etc.
When operating the maintenance switch, follow the
procedure in Chapter 1 (7. Resetting and Clearing
the Server) in this manual.
If the problem persists, contact your sales
representative.
Add more batteries for the capacity increase, or
reduce the number of devices that need battery
backup. If the problem persists, contact your sales
representative.
Make sure that the battery is correctly installed. If
the problem persists, contact your sales
representative.
Restart the server. If the problem persists, contact
your sales representative.
Contact your sales representative.
Action is not necessary.
Action is not necessary.
1. IML Error Message
183