Chapter 3 Appendix
Class
Error code
Secure Boot - Unable to reset one or
UEFI
2225
more keys.
Secure Boot - Unable to delete one or
UEFI
2226
more variables.
Secure Boot - Unable to delete one or
UEFI
2227
more entries.
UEFI
2319
Test event. This is only a test.
Slot %1 SAN Error - SAN link is down.
UEFI
2400
SAN connection not possible.
Slot %1 SAN Error - Fabric Login
UEFI
2401
(FLOGI) failed. SAN connection not
possible.
Slot %1 SAN Error - Name Server login
UEFI
2402
failed. Boot from SAN not possible.
Slot %1 SAN Error - No targets found.
UEFI
2403
Boot from SAN not possible.
Slot %1 SAN Error - Adapter restart
UEFI
2404
failed. Firmware not ready. Boot from
SAN not possible.
Slot %1 Error - Vital Product Data
UEFI
2405
(VPD) is not available.
Slot %1 NIC Error - NIC personality
UEFI
2406
(Ethernet, iSCSI, or FCoE) could not be
changed. FW may require update.
Slot %1 Error - The firmware update
UEFI
2407
did not complete successfully.
Slot %1 Error - Firmware image
UEFI
2408
recovery not successful.
200
Error message
Express5800/R120h-1M, R120h-2M Maintenance Guide
Action
Set the required settings again using the System
Utility after restoring factory default settings by
selecting System Configuration >
BIOS/Platform Configuration (RBSU) >
System Defult Options - Restore Default
Manufacturing Settings options from the menu of
the System Utility. If the problem persists, contact
your sales representative.
Set the required settings again using the System
Utility after restoring factory default settings by
selecting System Configuration >
BIOS/Platform Configuration (RBSU) >
System Defult Options - Restore Default
Manufacturing Settings options from the menu of
the System Utility. If the problem persists, contact
your sales representative.
Set the required settings again using the System
Utility after restoring factory default settings by
selecting System Configuration >
BIOS/Platform Configuration (RBSU) >
System Defult Options - Restore Default
Manufacturing Settings options from the menu of
the System Utility. If the problem persists, contact
your sales representative.
Action is not necessary.
Confirm the SAN switches and the configuration.
Then reconnect SAN ports or restart the server.
Confirm the SAN switches and the configuration.
Then reconnect SAN ports or restart the server.
Confirm the SAN switches and the configuration.
Then reconnect SAN ports or restart the server.
Confirm the SAN switches and the configuration.
Then reconnect SAN ports or restart the unit.
Reconnect SAN ports or restart the server. If the
problem persists, contact your sales
representative.
Update the firmware of the card in slot %1. If the
problem persists, contact your sales
representative.
Update the firmware of the NIC card in slot %1
before restarting the server.
Update the firmware of the card again after
confirming the firmware image of the card in
slot %1 is correct.
Restart the unit. If the problem persists, contact
your sales representative.