Chapter 3 Appendix
Class
Error code
Uncorrectable Memory Error Threshold
Exceeded (%1 %2, DIMM %3). The
UEFI
462
DIMM is mapped out and is currently
not available.
IMPORTANT: The UEFI Variable space is
close to exceeding the non-volatile
UEFI
471
storage capacity. This may impact OS
installations and may limit the ability to
configure certain options.
MemBIST RMT: %1 margin out of range
UEFI
3010
at CPU %2 DIMM %3 - Count %4
MemBIST MEMTEST: UnCorrectable
UEFI
3011
Memory Error found at CPU %1
DIMM %2 Rank %3 - UC Count %4
MemBIST MEMTEST: Correctable
Memory Error found at CPU %1
UEFI
3012
DIMM %2 Rank %3 Strobe %4 - CE
Count %5
Processor Built-In Self-Test (BIST)
UEFI
3013
Failure. Processor %1, Error Code =
0x%2.
(4) The list of messages about the power supply
Error
Class
code
Power
15
Power
1B
Power
1C
Power
1E
Power
24
Power
28
Power
29
Power
2A
Power
2B
Power
2C
Error message
Error message
Mismatched Power Supply Installed
System Board Power Protection Fault
Power Supply or Power Backplane
Detection Error
Smart Storage Battery Removed
(Battery %1)
Power On Denied (Service
Information: %1)
System Power Supply: %1 (Power
Supply %2)
External Chassis Power Supply: %1
(Chassis %2, Power Supply %3)
%1 Storage System Power Supply: %2
(%3Slot %4, Power Supply %5)
%1 Power Supply: %2 (Power
Supply %3, %4)
System Power Supply Removed (Power
Supply %1)
Express5800/R120h-1M, R120h-2M Maintenance Guide
Action
Contact your sales representative.
Restore the factory default settings using the
"Restore Default Manufacturing Settings" option
via System Configuration > BIOS/Platform
Configuration (RBSU) > System Defult Options
in the system utility. If the problem persists,
contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Action
Confirm the PSU mounted on the unit.
If the problem persists, contact your sales
representative.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Action is not necessary.