NEC Express5800/R120h-2M Maintenance Manual page 190

Nec express server. express5800 series
Hide thumbs Also See for Express5800/R120h-2M:
Table of Contents

Advertisement

Chapter 3 Appendix
Class
Error code
NVDIMM Error - Processor %1,
DIMM %2 (SN:%3-%4-%5-%6).
Unable to set event notification for this
UEFI
394
NVDIMM to generate alerts for health
changes, including a loss of data
persistency.
NVDIMM Error - Processor %1,
DIMM %2 (SN:%3-%4-%5-%6).
UEFI
395
NVDIMM Persistency is lost and future
data backup is not available.
IMPORTANT: Processor %1, DIMM %2 -
UEFI
396
NVDIMM Persistency is restored and
future data backup is available.
WARNING: Processor %1, DIMM %2
UEFI
397
(SN:%3-%4-%5-%6). NVDIMM
lifetime has reached.
NVDIMM Configuration Error -
Processor %1, DIMM %2
UEFI
398
(SN:%3-%4-%5-%6). Backup power is
not available to this DIMM slot.
NVDIMM is disabled.
INFORMATION: Processor %1,
DIMM %2 (SN:%3-%4-%5-%6).
UEFI
399
Extended Diagnostic Information
(Data1 = 0x%7, Data2 = 0x%8, Data3
= 0x%9, Data4 = 0x%10).
Intrusion Alert Detection - The server
UEFI
400
chassis hood is currently not installed.
Intrusion Alert Detection - The server
UEFI
401
chassis hood was removed prior to this
power on.
Intrusion Alert Detection - The required
UEFI
402
intrusion detection cable is missing.
Intrusion Alert Configuration Error -
UEFI
403
Intrusion Alert Detection cable is
installed but the feature is not enabled.
190
Error message
Express5800/R120h-1M, R120h-2M Maintenance Guide
Action
Updating the system ROM and the innovation
engine firmware may solve the error. Please update
the system ROM and the innovation engine
firmware.
If the problem persists, contact your sales
representative.
Please take actions in following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
Action is not necessary.
Please take actions in following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
Install the NVDIMM in the slot where the NVDIMM
is available. If the problem persists, contact your
sales representative.
Action is not necessary.
However, if the error is recorded repeatedly, please
contact your sales representative.
An intrusion warning has been detected. The cover
of the server has not been installed. Check the
installation of the cover.
If the problem persists, contact your sales
representative.
An intrusion warning has been detected. It
detected that the server cover has been once
removed. Check the status of the server.
If the problem persists, contact your sales
representative.
An intrusion warning has been detected. The
intrusion detection cable is not connected. Check
the status of the server.
If the problem persists, contact your sales
representative.
An intrusion warning has been detected. While the
intrusion detection cable has been connected, its
function is not enabled. Check the settings of the
server.
If the problem persists, contact your sales
representative.
1. IML Error Message

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/r120h-1mExp810Exp807

Table of Contents