Parameter
NV_CYCLE_T
FREE_SPACE
FREE_TIME
SHED_RCAS
SHED_ROUT
FAULT_STATE
SET_FSTATE
CLR_FSTATE
MAX_NOTIFY
LIM_NOTIFY
CONFIRM_ TIME
WRITE_LOCK
UPDATE_EVT
BLOCK_ALM
ALARM_SUM
ACK_OPTION
WRITE_PRI
WRITE_ALM
ITK_VER
Rev.5
Minimum time interval specified by the manufacturer for writing copies
of NV parameters to non-volatile memory. Zero implies it is never
automatically copied. At the end of NV_CYCLE_T, only those
parameters that have changed need to be updated in NVRAM.
Percent of memory available for further configuration. Zero in
preconfigured resource.
Percent of the block processing time that is free to process additional
blocks.
Time duration at which to give up on computer writes to function block
RCas locations. Shed from RCas does not happen, if SHED_RCAS =
0.
Time duration at which to give up on computer writes to function block
ROut locations. Shed from Rout does not happen, if SHED_ROUT =
0.
Condition set by loss of communication to an output block, fault
promoted to an output block or a physical contact. When Fault State
condition is set, output function blocks perform their FSTATE actions.
Allows the Fault State condition to be manually initiated by selecting
Set.
Writing a Clear to this parameter removes the device fault state if the
field condition, if any has cleared.
Maximum numbers of unconfirmed notify messages possible.
Maximum numbers of unconfirmed alert notify messages allowed.
The time the resource waits for confirmation of receipt of a report
before trying again. Retry does not happen when CONFIRM_TIME=0.
If set, no writes from anywhere are allowed, except to clear
WRITE_LOCK. Block inputs continues to be updated.
This alert is generated by any change to the static data.
The BLOCK_ALM is used for configuration, hardware, and connection
failure or system problems in the block. The cause of the alert is
entered in the subcode field. The first alert to become active sets the
Active status in the Status attribute. When the Unreported status is
cleared by the alert reporting task, another block alert is reported
without clearing the Active status, if the subcode has changed.
The current alert status, unacknowledged states, unreported states,
and disabled states of the alarms associated with the function block.
Selection of whether alarms associated with the block is automatically
acknowledged.
Priority of the alarm generated by clearing the write lock.
This alert is generated if the write lock parameter is cleared.
Major revision number of the interoperability test case used in
certifying this device as interoperable. The format and range are
controlled by the Fieldbus Foundation. The current ITK version is
6.1.1.