Vapor
Upper product
Lower product
These are available on the Attenuation Model panel shown in Figure
For each possible medium in the tank there is also a reference point from which the linear attenuation
should be applied. For the Surface and End of Probe reflections this reference point is the transmitter's
Reference Plane. For the Interface reflection this reference point is the location of the Surface
reflection in non-flooded applications and the location of the transmitter's Reference Plane for flooded
applications. The Reflection Model panel has entry fields where the locations of these reference points
can be entered. In many cases, these locations will have been determined by the transmitter and these
entry fields will be pre-populated with the correct values from the echo curve data.
Page 146
Figure 34 – Attenuation model
FOUNDATION Fieldbus Option User's Guide
34.
Rev. 3.0