POWER CABLING
6.2

BRAKE RESISTOR CABLES

Table 21: Brake resistor cables, 208-240 V and 380-500 V
Enclosure size
MR8
MR9
MR10
MR12
One of the cable conductors stays unconnected. Use a symmetrically shielded cable, same
type as the mains and motor cables.
NOTE!
The different VACON
VACON
100 FLOW does not have the dynamic braking or the brake resistor
®
functions.
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
Type
IL [A]
0140 2
140
0140 5
0170 2
170
0170 5
0205 2
205
0205 5
0261 2
261
0261 5
0310 2
310
0310 5
0385 5
385
0460 5
460
0520 5
520
0590 5
590
0650 5
650
0730 5
730
0820 5
820
0920 5
920
1040 5
1040
1180 5
1180
100 applications have different functions. For example, the
®
Brake resistor
Brake resistor
cable (Cu) [mm
2
]
cable (Cu) [AWG/
3x70+35
3x95+50
3x120+70
2x(3x70+35)
2x(3x95+50)
2x(3x95+50)
2x(3x120+70)
4x(3x95+50)
4x(3x120+70)
VACON · 57
kcmil]
4/0
300
350
2x3/0
2x4/0
2x4/0
2x250
4x4/0
4x250
6