VACON · 116
10.1.2
MAINS VOLTAGE 380-500 V
Table 45: The power ratings of VACON
Enclosure
Drive type
size
MR8
0140
0170
0205
MR9
0261
0310
MR10
0385
0460
0520
0590*
MR12
0650
0730
0820
0920
1040*
1180*
10
100 FLOW in mains voltage 380-500 V, 50-60 Hz, 3~
®
Loadability
Continuous
Input
current
current I
Lin
I
[A]
[A]
Lout
140.0
139.4
170.0
166.5
205.0
199.6
261.0
258.0
310.0
303.0
385.0
385.0
460.0
460.0
520.0
520.0
590.0
590.0
650.0
648.0
730.0
724.0
820.0
822.0
920.0
916.0
1040.0
1030.0
1180.0
1164.0
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
TECHNICAL DATA, VACON® 100 FLOW
10%
Max
overload
current I
S
current [A]
2s
154.0
210.0
187.0
280.0
225.5
340.0
287.1
410.0
341.0
502.0
423.5
620.0
506.0
770.0
572.0
920.0
649.0
1040.0
715.0
1180.0
803.0
1300.0
902.0
1460.0
1012.0
1640.0
1144.0
1840.0
1298.0
1840.0
Motor shaft power
400 V
480 V
mains
mains
10%
10%
overload
overload
40°C [kW]
40°C [hp]
75.0
100.0
90.0
125.0
110.0
150.0
132.0
200.0
160.0
250.0
200.0
300.0
250.0
350.0
250.0
450.0
315.0
500.0
355.0
500.0
400.0
600.0
450.0
700.0
500.0
800.0
560.0
900.0
630.0
1000.0
Need help?