When The Operation Of The Emulator Is Abnormal; Self-Check Procedure In The Self-Check Mode - Renesas M30800T-CPE User Manual

Table of Contents

Advertisement

5.3 When the Operation of the Emulator is Abnormal

Self-check is a function to check the state of the memory etc. mounted on the emulator. Self-check
is executed when the emulator starts up, and detailed checks are executed by following the procedure
below.
For this self-check, be sure to disconnect the target system. Set each switch as listed in Table 5.5.
Table 5.5 Switch setting when executing self-check

(1) Self-check Procedure in the Self-check Mode

Figure 5.2 Self-check procedure
Switch
MCU power supply select jumper (JP1)
MCU power voltage select jumper (JP2)
P8
/X
select switch
7
CIN
POWER CLOCK
RESET
RUN
LED3
LED4
LED5
LED6
POWER CLOCK
RESET
RUN
LED3
LED4
LED5
LED6
POWER CLOCK
RESET
RUN
LED3
LED4
LED5
LED6
Blinking in
Target status
succession
LEDs repeat
succession?
Status of SAFE LED
When self-checks terminated normally
POWER CLOCK
RESET
RUN
LED3
LED4
LED5
LED6
For starting up the emulator after the self-
check, shut off the power of the emulator and
reactivate it.
Setting
INT side
5.0 V side
XCIN side
POWER
SAFE
LED1
LED2
POWER
SAFE
LED1
LED2
POWER
SAFE
LED1
LED2
For this self-check, it takes about 30 seconds (XIN = 20 MHz)
blinking in
Blinking finished
SAFE LED: OFF
SAFE LED: ON
POWER
SAFE
LED1
LED2
SAFE LED is turned OFF and one or more
target status LEDs repeat blinking according
to the error type.
( 44 / 52 )
(1) Within 2 seconds of activating power
to the emulator, press the RESET
switch.
(2) Press the system reset switch again
after checking SAFE LED blinks.
(3) Target status LEDs repeat blinking
in succession.
When error detected
POWER CLOCK
RESET
RUN
LED3
LED4
LED5
LED6
LED display
ON Blinking OFF
POWER
SAFE
LED1
LED2

Advertisement

Table of Contents
loading

Table of Contents