Absolute Position Detection System - Mitsubishi Melservo-J2-Super series Instruction Manual

General-purpose ac servo. sscnet fully closed control compatible
Table of Contents

Advertisement

4. OPERATION AND FUNCTIONS

4.5 Absolute position detection system

An ABS type linear scale is necessary to configure an absolute position detection system under full closed
control using a linear scale.
In this case, absolute value data are backed up on the linear scale side, and therefore, the encoder battery
(MR-BAT) need not be installed to the servo amplifier.
[Precautions]
Make setting to make Absolute position detection valid in the servo parameter (Pr. 1
can be used in the following limited conditions.
(1) Using conditions
1) Use an absolute type linear scale with the full closed encoder.
2) Select Always full closed (Pr. 62
(2) Absolute position detection range using encoder
Linear scale
(Serial I/F)
(3) Alarm detection
The absolute position-related alarm (25) and warnings (92, 9F, E3) are not detected.
POINT
When configuring an absolute position detection system with this servo
amplifier under semi closed control, the encoder battery (MR-BAT) must
be installed to the servo amplifier like the standard amplifier.
At this time, the option cable (MR-J2SCLCBL02M-P-H) cannot be used.
Connect the encoder cable of the motor encoder directly to the servo
amplifier.
1).
Encoder Type
Movable distance range of scale
(within 32-bit absolute position data)
Absolute Position Detection Enabled Range
4 - 19
0001). The system

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: