Mitsubishi Melservo-J2-Super series Instruction Manual page 37

General-purpose ac servo. sscnet fully closed control compatible
Table of Contents

Advertisement

2. LINEAR SCALES
(2) Connection example of 5m to 30m wiring length (This connection example assumes that the following
operating combination is satisfied.)
[Operating combination]
Used Wire Size
AWG22
[Connection example]
The wiring length is up to 30m. Depending on the wiring length, however, the number of LG and P5
connections must be changed according to the following table.
10120-3000PE, 10320-52F0-008
(3M make or equivalent)
Servo amplifier
MR-J2S- B
CN2
-PY096/S096
19
P5
12
LG
20
P5
11
LG
7
MR
17
MRR
1
LG
6
MD
16
MDR
Plate
SD
[Linear encoder side connector] (Note 6)
Applicable
D Sub 15 Pin Female
Housing
Inner
P5
LG
MR
MRR
SD
Note 1. Do not connect the linear encoder (linear scale) that is not indicated in this specification.
2. Connect the shield wire to the plate (ground plate) in the connector securely.
3. For the wiring to the servo motor, refer to the standard connection examples in Chapter 3 and the Instruction Manual of the MR-
J2S- B standard model.
4. A limit switch signal cannot be imported directly to the servo amplifier. When using a limit switch, use a photocoupler for
isolation as shown above. Contact the scale manufacturer for detailed specifications of the limit switch.
5. The encoder (scale) home position (reference mark) data is sent to the servo amplifier by serial communication.
6. Contact the scale manufacturer for detailed specifications such as the combinations, models, types, etc. of the linear encoder
(linear scale) side output cable and connector.
Encoder (Scale) Model
RGH26
50m or less (2 wire type)
(Note 3)
(Note 2)
Limit switch output (Note 4)
30m or less
Equivalent
15
7, 8
2, 9
10
1
Case
Encoder (Scale) Side Output Cable Specifications
Renishaw make output cable 0.5m
Servo motor
(Note 1)
P5
LG
MR
MRR
P5
LG
Inner
/P
/Q
SD
(Note 5)
2 - 18
Wiring
Number of LG and P5
Length
Connections
to 5m
2 parallel
to 10m
3 parallel
to 15m
4 parallel
to 20m
5 parallel
to 25m
6 parallel
to 30m
7 parallel
Renishaw make
linear encoder (linear scale)
5V
/P, /Q
0V
Photocoupler
isolation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j2s-*b-py096 seriesMr-j2s-*b-s096 series

Table of Contents