4. OPERATION AND FUNCTIONS
[Method for always making home position return to the same position]
(a) Move the linear servo motor to the position where the stroke end signal on the side opposite to the
home position return direction turns on.
Machine position
(b) Perform the power-on reset of the servo amplifier or reset the controller.
(c) Switch on the servo and make a home position return.
Home position return operation
ON
Proximity dog
OFF
signal
Machine position
Stroke end
Scale home position
Home position return speed
Scale home position
Stroke end
Home position return direction
Creep speed
4 - 13
Home position
Home position