Mitutoyo Make Linear Scales (Abs Type) - Mitsubishi Melservo-J2-Super series Instruction Manual

General-purpose ac servo. sscnet fully closed control compatible
Table of Contents

Advertisement

2. LINEAR SCALES

2.1.1 Mitutoyo make linear scales (ABS type)

Specifications Reference
Contact Mitutoyo for the specifications of these linear scales.
Item
Model
System
Effective measurement length
Resolution
Indication accuracy (20 )
Supply power voltage
Current consumption
Rated response speed
Maximum response speed
Operating temperature range
Operating humidity range
Storage temperature range
Storage humidity range
Dust tightness water tightness
Vibration resistance
Shock resistance
Sliding force
Output signal
Output cable
Connection cable
(Mitsubishi option)
Note 1. The MR-JCCBL M-L and MR-JCCBL20M-H and more (20m and more) cannot be used.
2. The battery (MR-BAT) is not required to configure an absolute position detection system.
Scale unit structure Reference
Mitutoyo
Output cable
Mitutoyo
Output cable
Head cable
AT343A-
100 to 3000mm
100 to 1500mm: 3 3L/1000 m
1600mm to 3000mm: 5 5L/1000 m
L: Effective measurement length
Max.250mA
0 to 45
(non-freezing)
(in the indication method given in the instruction manual of the Mitutoyo make linear scale)
100m/s
(55 to 2000Hz)
2
150m/s
(1/2sin, 11ms)
2
Mitutoyo make option
Part No. 09BAA598A to C:0.2, 2, 3m
Refer to the standard connection example in
Chapter 3 and fabricate the cable.
When the MR-J2SCLCBL02M-P-H is used,
any of the following Mitsubishi cables can also
be used (Note 1).
Output cable length 0.2m: MR-JCCBL2, 5,
2m: MR-JCCBL2, 5M-H
3m: MR-JCCBL2M-H
Home position
Decreasing direction
Increasing direction
Home position
Decreasing direction
Increasing direction
Specifications
Capacitive, photoelectric, combined type
0.05 m
5V 5%
2.0m/s
2.0m/s
20 to 80%RH (non-condensing)
20 to 70
(non-freezing)
20 to 80%RH (non-condensing)
IP53 or equivalent
5N or less
Serial communication compatibility
Refer to the standard connection example in
Chapter 3 and fabricate the cable.
When the MR-J2SCLCBL02M-P-H is used,
any of the following Mitsubishi cables can also
be used (Note 1).
MR-JCCBL2, 5, 10M-H
10M-H
AT343A
AT543A
2 - 2
AT543A-
100 to 1500mm
100 to 1500mm: 3 3L/1000 m
L: Effective measurement length
Max.270mA
0 to 50
(non-freezing)
150m/s
(55 to 2000Hz)
2
200m/s
(1/2sin, 11ms)
2
Supplied as standard
Head cable 5m output cable 1m

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j2s-*b-py096 seriesMr-j2s-*b-s096 series

Table of Contents