B.4 MEMORY MAPPING
bitmask
element
5
Phase Instantaneous Overcurrent 6
6
Phase Instantaneous Overcurrent 7
7
Phase Instantaneous Overcurrent 8
8
Phase Instantaneous Overcurrent 9
9
Phase Instantaneous Overcurrent 10
10
Phase Instantaneous Overcurrent 11
11
Phase Instantaneous Overcurrent 12
16
Phase Time Overcurrent 1
17
Phase Time Overcurrent 2
18
Phase Time Overcurrent 3
19
Phase Time Overcurrent 4
B
20
Phase Time Overcurrent 5
21
Phase Time Overcurrent 6
24
Phase Directional Overcurrent 1
25
Phase Directional Overcurrent 2
32
Neutral Instantaneous Overcurrent 1
33
Neutral Instantaneous Overcurrent 2
34
Neutral Instantaneous Overcurrent 3
35
Neutral Instantaneous Overcurrent 4
36
Neutral Instantaneous Overcurrent 5
37
Neutral Instantaneous Overcurrent 6
38
Neutral Instantaneous Overcurrent 7
39
Neutral Instantaneous Overcurrent 8
40
Neutral Instantaneous Overcurrent 9
41
Neutral Instantaneous Overcurrent 10
42
Neutral Instantaneous Overcurrent 11
43
Neutral Instantaneous Overcurrent 12
48
Neutral Time Overcurrent 1
49
Neutral Time Overcurrent 2
50
Neutral Time Overcurrent 3
51
Neutral Time Overcurrent 4
52
Neutral Time Overcurrent 5
53
Neutral Time Overcurrent 6
56
Neutral Directional Overcurrent 1
60
Negative Sequence Directional Overcurrent 1
61
Negative Sequence Directional Overcurrent 2
64
Ground Instantaneous Overcurrent 1
65
Ground Instantaneous Overcurrent 2
66
Ground Instantaneous Overcurrent 3
67
Ground Instantaneous Overcurrent 4
68
Ground Instantaneous Overcurrent 5
69
Ground Instantaneous Overcurrent 6
70
Ground Instantaneous Overcurrent 7
71
Ground Instantaneous Overcurrent 8
72
Ground Instantaneous Overcurrent 9
73
Ground Instantaneous Overcurrent 10
74
Ground Instantaneous Overcurrent 11
75
Ground Instantaneous Overcurrent 12
80
Ground Time Overcurrent 1
81
Ground Time Overcurrent 2
82
Ground Time Overcurrent 3
83
Ground Time Overcurrent 4
84
Ground Time Overcurrent 5
B-72
C70 Capacitor Bank Protection and Control System
bitmask
element
85
Ground Time Overcurrent 6
96
Negative Sequence Instantaneous Overcurrent 1
97
Negative Sequence Instantaneous Overcurrent 2
112
Negative Sequence Time Overcurrent 1
113
Negative Sequence Time Overcurrent 2
120
Negative Sequence Overvoltage
144
Phase Undervoltage 1
145
Phase Undervoltage 2
148
Auxiliary Overvoltage 1
152
Phase Overvoltage 1
154
Compensated Overvoltage 1
156
Neutral Overvoltage 1
224
SRC1 VT Fuse Failure
225
SRC2 VT Fuse Failure
226
SRC3 VT Fuse Failure
227
SRC4 VT Fuse Failure
228
SRC5 VT Fuse Failure
229
SRC6 VT Fuse Failure
232
SRC1 50DD (Disturbance Detection)
233
SRC2 50DD (Disturbance Detection)
234
SRC3 50DD (Disturbance Detection)
235
SRC4 50DD (Disturbance Detection)
236
SRC5 50DD (Disturbance Detection)
237
SRC6 50DD (Disturbance Detection)
280
Breaker Failure 1
281
Breaker Failure 2
282
Breaker Failure 3
283
Breaker Failure 4
284
Breaker Failure 5
285
Breaker Failure 6
294
Breaker 1 Flashover
295
Breaker 2 Flashover
336
Setting Group
337
Reset
340
Neutral voltage unbalance 1
341
Neutral voltage unbalance 2
342
Neutral voltage unbalance 3
388
Selector 1
389
Selector 2
390
Control pushbutton 1
391
Control pushbutton 2
392
Control pushbutton 3
393
Control pushbutton 4
394
Control pushbutton 5
395
Control pushbutton 6
396
Control pushbutton 7
400
FlexElement 1
401
FlexElement 2
402
FlexElement 3
403
FlexElement 4
404
FlexElement 5
405
FlexElement 6
406
FlexElemen 7