B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 17 of 61)
ADDR
REGISTER NAME
3FDC
...Repeated for Field Unit 5
3FE5
...Repeated for Field Unit 6
3FEE
...Repeated for Field Unit 7
3FF7
...Repeated for Field Unit 8
Passwords (Read/Write Command)
4000
Command Password Setting
Passwords (Read/Write Setting)
400A
Setting Password Setting
Passwords (Read/Write)
4014
Command Password Entry
B
401E
Setting Password Entry
Passwords (Read Only)
4028
Command Password Status
4029
Setting Password Status
Passwords (Read/Write Setting)
402A
Command Password Access Timeout
402B
Setting Password Access Timeout
402C
Invalid Password Attempts
402D
Password Lockout Duration
Passwords (Read/Write)
402E
Password Access Events
Passwords (Read/Write Setting)
402F
Local Setting Auth
4031
Remote Setting Auth
4033
Access Auth Timeout
User Display Invoke (Read/Write Setting)
4040
Invoke and Scroll Through User Display Menu Operand
LED Test (Read/Write Setting)
4048
LED Test Function
4049
LED Test Control
Preferences (Read/Write Setting)
404F
Language
4050
Flash Message Time
4051
Default Message Timeout
4052
Default Message Intensity
4053
Screen Saver Feature
4054
Screen Saver Wait Time
4055
Current Cutoff Level
4056
Voltage Cutoff Level
Communications (Read/Write Setting)
407D
COM2 Selection
407F
COM2 Minimum Response Time
4080
Modbus Slave Address
4085
RS485 Com2 Baud Rate
4086
RS485 Com2 Parity
4087
IP Address
4089
IP Subnet Mask
408B
Port 1 Gateway IP Address
4097
Port 1 Link Loss Alert
4098
Port 2 Link Loss Alert
4099
Port 3 Link Loss Alert
409A
DNP Channel 1 Port
409B
DNP Channel 2 Port
409C
DNP Address
B-24
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
1 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
10 to 900
1 to 65535
0.002 to 0.02
0 to 1000
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65519
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
---
1
---
1
---
1
---
1
0 to 1
---
1
0 to 1
---
1
5 to 480
min
1
5 to 480
min
1
2 to 5
---
1
5 to 60
min
1
0 to 1
---
1
---
1
---
1
5 to 480
min
1
---
1
0 to 1
---
1
---
1
0 to 3
---
1
0.5 to 10
s
0.1
s
1
0 to 3
---
1
0 to 1
---
1
min
1
pu
0.001
0.1 to 1
V
0.1
0 to 3
---
1
ms
10
1 to 254
---
1
0 to 11
---
1
0 to 2
---
1
---
1
---
1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
0 to 5
---
1
---
1
APPENDIX B
FORMAT
DEFAULT
F202
0
F202
0
F202
(none)
F202
(none)
F102
0 (Disabled)
F102
0 (Disabled)
F001
5
F001
30
F001
3
F001
5
F102
0 (Disabled)
F300
1
F300
1
F001
30
F300
0
F102
0 (Disabled)
F300
0
F531
0 (English)
F001
10
F001
300
F101
0 (25%)
F102
0 (Disabled)
F001
30
F001
20
F001
10
F601
0 (RS485)
F001
0
F001
254
F112
8 (115200)
F113
0 (None)
F003
56554706
F003
4294966272
F003
56554497
F102
0 (Disabled)
F102
0 (Disabled)
F102
0 (Disabled)
F177
0 (None)
F177
0 (None)
F001
1
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents