Canon BJ-W9000 Service Manual page 129

Table of Contents

Advertisement

BJ-W9000
54) Wb102
Spur sensor warning
The spur sensor failed to detect the reference position (the position where the sensor
light passes through) within the prescribed time, when power was turned on
55) Eb103
Suction cap sensor error
The suction cap sensor failed to detect the reference position (the position where the
sensor light passes through) within the prescribed time, when power was turned on.
56) Eb104
Protective cap/wiper up-down sensor error (when driving the wiper)
The Protective cap/wiper up-down sensor failed to detect the reference position (the
position where the sensor light passes through) within the prescribed time, when
power was turned on.
57) Eb105
A-H valve sensor error
The A-H valve sensor failed to detect the reference position (the position where the
sensor light passes through) within the prescribed time, when power was turned on.
58) Eb106
Cover open/close arm sensor error
The cover open/close arm sensor failed to detect the reference position (the position where
the sensor light passes through) within the prescribed time, when power was turned on.
59) Eb107
Wiper blade sensor error
The wiper blade sensor failed to detect the reference position (the position where the
sensor light passes through) within the prescribed time, when power was turned on.
60) Eb201
A-C/C-S valve sensor error
The A-C/C-S valve sensor error failed to detect the reference position (the position
where the sensor light passes through) within the prescribed time, when power was
turned on.
61) Eb202
Y/PC/PM air valve sensor error
The Y/PC/PM air valve sensor failed to detect the reference position (the position
where the sensor light passes through) within the prescribed time, when power was
turned on.
62) Eb203
C/M/K air valve sensor error
The C/M/K air valve sensor failed to detect the reference position (the position
where the sensor light passes through) within the prescribed time, when power was
turned on.
63) Eb204
Pump valve sensor error
The pump valve sensor failed to detect the reference position (the position where the
sensor light passes through) within the prescribed time, when power was turned on.
3-79