Digital Inputs And Outputs - Lenze 8400 Hardware Manual

E84a series
Hide thumbs Also See for 8400:
Table of Contents

Advertisement

6.8.3

Digital inputs and outputs

X5
Fig. 6-42
Labelling
RFR
DI1
DI2
DI3
DI4
DI5
DI6
DI7
GI
Terminal data
Flexible
With wire end ferrule
EDS84ASC552 EN 10.0
Connection of the digital inputs
Description
Controller enable/controller inhibit, always required
Digital input 1
 82
IEC61131-2, type 1 or two-track frequency input, for HTL
Digital input 2
encoder 0 ... 200 kHz
Digital input 3
 82
Digital input 4
IEC61131-2, type 1
Digital input 5
Digital input 6
IEC61131-2, type 1 or
two-track frequency input for HTL encoder 0 ... 10 kHz
Digital input 7
GND digital inputs
Conductor cross-section
2
[mm
]
0.2 ... 1.5
Electrical installation
HighLine C control terminals
Digital inputs and outputs
GND-I
X5
GI
DI7
DI6
DI5
DI4
8400HLC036
Tightening torque
[AWG]
[Nm]
24 ... 16
-
24 V int.
DI3
DI2
DI1
RFR
24I
24E
DC 24 V
S1
(+19.2...
+28.8 V)
8400HLC045
track A
track B
[lb-in]
-
-
235
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8400 stateline c8400 highline c8400 topline c

Table of Contents