Rated Data - Lenze 8400 Hardware Manual

E84a series
Hide thumbs Also See for 8400:
Table of Contents

Advertisement

Integrated brake control for devices of the HighLine/TopLine version
ƒ
Range
Input voltage
Input current
Output voltage
Maximum brake current
Internal control
Maximally connectable
cable cross-section
Further technical data regarding the brake control can be found in chapter
4.7.7.
EDS84ASC552 EN 10.0
Operation with spring-applied brake
Values
DC 24 V in accordance with IEC 61131-2
19.2 ... 28.8 V
DC 0.1 ... 2.6 A
DC 24 V
DC 2.5 A
Information on internal brake control is provided in the software manual for the
Inverter Drives 8400 HighLine C / TopLine C.
2
1.5 mm
AWG 16
Braking operation

Rated data

8
263