6
Electrical installation
StateLine C control terminals

Digital inputs and outputs

6.7.3
Digital inputs and outputs
X4
Fig. 6-36
Labelling
RFR
DI1
DI2
DI3
DI4
DO1
GIO
Terminal data
Flexible
With wire end ferrule
228
Connection of the digital inputs and outputs
Description
Controller enable/controller inhibit, always required
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Digital output 1
GND digital signals
Conductor cross-section
2
[mm
]
0.2 ... 1.5
GND-IO
GIO
DO1
DI4
DI3
X4
8400SLC044
 79
IEC61131-2, type 1 or two-track frequency input, for
HTL encoding 0 ... 10 kHz
 79
 79
Tightening torque
[AWG]
[Nm]
24 ... 16
-
GND-IO
24 V int.
DI2
DI1
RFR
24I
24E
DC 24 V
(+19.2...
S1
+28.8 V)
8400SLC045
track A
track B
[lb-in]
-
-
EDS84ASC552 EN 10.0