5
Mechanical installation
Standard devices in a power range of 0.25 ... 3 kW

Assembly in push-through technique (thermal separation)

5.2.2
Assembly in push-through technique (thermal separation)
The E84AVxxD... controllers are designed for mounting in push-through design. The scope
of supply includes all parts required for mounting.
Installation steps
How to proceed:
1. Prepare mounting cutout and mounting holes (threaded holes M5 recommended).
2. Insert the 8400 frequency inverter into the mounting cutout.
3. Tighten with 6 screw and washer assemblies M5 x 10 (cross screw connection
recommended).
4. Seal the screws to ensure the IP54 enclosure or UL type 12.