4.3

Control of MOBILE DCU, PSU, DCU PSU

The MOBILE device is controlled via the X31 terminal.
4.3.1

Voltage supply

Voltage supply
Supply voltage TRM30
Rated voltage
Voltage range
Absolute voltage
(Pulse forms: ISO 16750−2)
(Behaviour: ISO 16750−1)
Current consumption
Quiescent current at T
Switch on/off device TRM15
Switching threshold
Current consumption
4.3.2

Digital inputs

Digital inputs
Rated input voltage
Voltage range
Digital HIGH
Digital LOW
Hysteresis
Input resistance
Reference potential
Diagnostics option
Digital frequency inputs FLX_IN3, FLX_IN4
Frequency range
Response time
Analog inputs FLX_IN1, FLX_IN2
Input frequency
Resolution
EDSMDAG EN 2.0
Control of MOBILE DCU, PSU, DCU PSU
V DC
V DC
Min.
V DC
Max.
V DC
A
mA
= 25 °C
amb
V DC
mA
V DC
V DC
V DC
V DC
V DC
kW
kHz
ms
Hz
Bit
Ò
Technical data
Voltage supply
LV on−board supply system
12 V
24 V
12
24
8 ... 36
8 ... 36
6
6
60
60
1 ... 2.5
0.5 ... 1.3
40 ... 60
40 ... 60
8
8
1.7
1.7
LV on−board supply system
12 V
24 V
12
24
8 ... 36
8 ... 36
7.8 ... 9
15.6 ... 18.2
3 ... 4.5
6.2 ... 8.8
3.3 ... 6
6.8 ... 12
4.75
TRM31
Wire breakage/short circuit
0 ... 10
90
0 ... 500
4096
4
31