Assembly In Push-Through Technique (Thermal Separation) - Lenze 8400 Hardware Manual

E84a series
Hide thumbs Also See for 8400:
Table of Contents

Advertisement

5.3.2

Assembly in push-through technique (thermal separation)

The E84AVxxD... controllers are designed for mounting in push-through design. The scope
of supply includes all parts required for mounting.
Installation steps
How to proceed:
1. Prepare mounting cutout and mounting holes (threaded holes M5 recommended).
2. Insert the 8400 frequency inverter into the mounting cutout.
3. Tighten with 6 screw and washer assemblies M5 x 10 (cross screw connection
recommended).
4. Seal the screws to ensure the IP54 enclosure or UL type 12.
StateLine, HighLine
Fig. 5-25
E84AVxxD3024xXx
E84AVxxD4024xXx
E84AVxxD5524xXx
E84AVxxD3024xBx
E84AVxxD4024xBx
E84AVxxD5524xBx
EDS84ASC552 EN 10.0
Standard devices in the power range 3 ... 22 kW
Assembly in push-through technique (thermal separation)
Device dimensions
h
b
[kW]
3
4
270
174
5.5
3
4
270
174
5.5
Mechanical installation
t
h
h
b
1
2
1
[mm]
141
318
366
140
161
318
366
140
5
8400GG106e
t
t
g
g
1
3
1
2
128
64
6
5
148
64
6
5
121

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8400 stateline c8400 highline c8400 topline c

Table of Contents