Overview Of Control Terminals - Lenze 8400 Hardware Manual

E84a series
Hide thumbs Also See for 8400:
Table of Contents

Advertisement

3.3

Overview of control terminals

Control terminals for devices in the StateLine version
Connection
Pos.
X1
S1
X3
X4
X5
X6 (DIAG)
X107
MMI
 Icon
EDS84ASC552 EN 10.0
Description
CANopen connection
CANopen settings
Analog inputs/outputs; 10V reference voltage
Digital inputs; controller enable
24 V supply of the control electronics
Digital outputs
24 V voltage output
Digital inputs; controller enable
External 24V supply of the control electronics; internal 24V supply
fused via PTC
Diagnostic interface
24 V brake supply;
+ BD1
Connection for DC brake coil
- BD2
Slot for memory module (Memory Module Interface)
Description
Long discharge time: All power terminals remain live for a few minutes after mains
disconnection! The duration is given under the warning symbol on the device.
High leakage current: Carry out fixed installation and PE connection according to EN 61800-5-1!
Electrostatic sensitive devices: Before working on the device, the personnel must be free of
electrostatic charge!
Hot surface: Risk of burns! Hot surfaces should not be touched without wearing protective
gloves.
Product description
Overview of control terminals
Control terminals for devices in the HighLine version
8400HLC080a
3
8400HLC081a
Information
StateLine C
HighLine C
 215
 225
 232
-
 236
 236
-
 235
 223
-
 238
 295
23