are resolved within 1 second, otherwise it will generate alarms. This can be overridden
by checking the "Treat ethernet events as alarms" box in the Setup - Params view

6.2.1 Alarms - All Alarms

The Alarms view gives the user the possibility of viewing alarms according to type or
as one complete list. The Ethernet alarms list, FSM alarms list, ETR alarms list and
System alarms list can hold 400, 100, 400 and 100 alarms respectively and are
independent of each other, meaning that one may become full without affecting the
other lists.
If Auto-refresh list is selected, the alarm list will be continuously updated with new
alarms. Active alarms are always located at the top of the list.
Clicking the View list offline button gives the user the opportunity to view all stored
alarms and events. By clicking one of the blue information icons leftmost in the offline
list, a detailed alarm description can be viewed. The search field in the upper right
corner of the view allows the user to type a text string and the alarm list is updated to
display only streams and alarms matching the specified text. To updated the offline
alarm list click the Auto-refresh list button and then go back to the offline mode.
PROBE USERS' MANUAL VERSION 5.0