alarms in the Alarms - Alarm Setup view.
Max bitrate: The maximum bitrate in Mbit/s. An alarm will be raised if the
stream bitrate exceeds the maximum bitrate.
Min bitrate: The minimum bitrate in Mbit/s. A value of 0 will never generate
an alarm. A value of 0.1Mbit/s will generate an alarm if the
minimum bitrate threshold is less than 0.1Mbit/s.
No signal: Number of milliseconds without receiving any signal before the
'No signal' alarm is raised
RTP drop limit: If the number of lost RTP packets exceeds the RTP drop limit an
alarm will be raised. Note that error seconds based on packet
drops are counted regardless of this threshold.
Ignore PID loss: A comma separated list of PIDs for which the probe should
ignore packet loss. Packet loss that affects these PIDs will not
result in an error-second count, and the ETR monitoring engine
will not count these errors.