Parsing rules for private descriptors
Probe recognition of a number of selected private descriptors may be defined by the
user:
129 (0x81): 'Disabled' or 'AC-3 audio stream descriptor'
131 (0x83): 'Disabled' or 'logical channel descriptor v1'
134 (0x86): 'Disabled' or 'caption service descriptor'
135 (0x87): 'Disabled', 'logical channel descriptor v2' or 'content advisory
161 (0xa1): 'Disabled', 'service location descriptor' or
162 (0xa2): 'Disabled' or 'etv_integrated_signaling_descriptor'
231 (0xe7): 'Disabled' or 'private cable delivery system descriptor'
233 (0xe9): 'Disabled' or 'ip_delivery_system_descriptor'
The default value for private descriptors is 'Disabled'. To change this value, select a
new descriptor interpretation from the drop-down menu and click the Apply changes
button.
ETR 290 tuning control
By default authorised users will be allowed to lock the ETR 290 analysis to one stream
for an infinite length of time and unauthorised users will not be allowed to lock the
analysis. The Setup - ETR view makes it possible to time limit the locking for
authorised users and unauthorised users can be granted permission to lock to a
stream for a selectable time period.
If the locking mechanism works in a time limited mode a clock icon is superimposed
on the regular lock icon in the different ETR 290 subviews. When the specified lock
time is out the round-robin cycling will resume. When ETR tuning control parameters
have been changed, click the Apply button for changes to take effect.