6.12 COFDM (VB250 Option Module for VB220)
The COFDM tab will only be present in the graphical user interface provided that the
probe chassis is equipped with an optional COFDM demodulator module.
Each COFDM tab represents an independent RF input. The VB250 has one RF input per
module. The VB252 has two RF inputs per module. COFDM1 is the leftmost input as
seen from the front of the unit. There can be up to four COFDM tabs (COFDM1 through
to COFDM4) depending on card configuration.
Thumbnails of COFDM services are accessed from the ETR 290 - Services view.
6.12.1 COFDM - Status (VB250)
The COFDM - Status view gives an overview of the key input interface parameters.
The COFDM status view displays the following information:
Packet length: Indicates if the transport stream packets are 188 or 204
Original network
Network ID: The network ID as specified in the NIT table
Transport stream
Total bitrate: Total transport stream bitrate including null packets (PID
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00 -
COFDM status - Stream info:
bytes
The original network ID as specified in the NIT table
ID:
The transport stream ID as specified in the PAT table
ID: