Simple P/P Output Signal Selection On An M/E - Sony MVS-6000 User Manual

Multi format switcher system with ccp-9000 series center control panel
Hide thumbs Also See for MVS-6000:
Table of Contents

Advertisement

2
3
To clear a primary input assignment
Press [Inhibit].
This clears the assignment and "No Assign" is displayed in the Re-Entry
column.

Simple P/P Output Signal Selection on an M/E

You can select a simple P/P output on an M/E.
Preparations
Interface connection
Connect the simple P/P output signal to return to a primary input via a BNC
cable.
System setup
In the Engineering Setup >Switcher >Output >Simple P/P R-Entry Assign
menu, specifies the primary input to which the simple P/P output signal returns.
Selecting the input on an M/E bank
Select a primary input on the cross-point control block of an M/E bank. You
can select a simple P/P output signal with the same phase as that of the other
input signals.
360
Simple P/P Software
The status area shows the output ports and assigned primary inputs on the
left, and a list of primary inputs that can be assigned on the right.
Using any of the following methods, select the output port number and
signal to be assigned.
• Press directly on the list in the status area to make the selection.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
Knob
Parameter
V1
Output No.
V2
Source No.
Press [Set].
This assigns the primary input to the selected output port.
Adjustment
Setting values
Output port number
1 to 23
Primary input number 0 to 49