FUTABA T12K Instruction Manual page 63

Digital propotional r/c system. t-fhss air-2.4ghz
Hide thumbs Also See for T12K:
Table of Contents

Advertisement

Stick calibration method
*J3 and J4 correction is described below. J1 and J2
corrections are performed using the same procedure.
1.Select [CALIBRATION] and access the setup
screen shown below by pushing the RTN
button.
2.Move the cursor to the J3-J4 button and push
the RTN button.
3.Move the J3 or J4 sticks to the neutral position
and push the RTN button for one second.
4.Set the J3 and J4 sticks fully to the bottom
right and wait until the buzzer sounds.
5.Set the J3 and J4 sticks fully to the top left and
wait until the buzzer sounds.
6 . T h e a b o v e c o m p l e t e s t h e c o r r e c t i o n
operation. Operate and check if stick
correction was performed normally.
<Functions of System Menu>