GOVERNOR mixing
When using a Futaba GV-1/GY701/CGY750
governor, this function is used to switch the RPM
of the helicopter's rotor head. The rotor head speed
can be switched with each condition or the switch.
*The governor is used by connecting the governor speed
setting channel to CH7 (initial setting).
● Select [GOVERNOR] at the Model menu and access
the setup screen shown below by pushing the RTN
button.
●Setup screen selection
●Condition/Switch selection
● Select the function name
and return to the Model
menu by pushing the RTN
button or pushing the
HOME/EXIT button.
RETURN
●Unit display selection:
[%]/[rpm]
Setting method
●Activate the mixing
When using this function, move the cursor to
the [INH] item and push the RTN button to
switch to the data input mode.
Select the ACT mode by scrolling the Push
dial.
*The display blinks.
Push the RTN button to activate the mixing
and return to the cursor mode. (ON is
displayed.)
 When the Governor is changed from the
default inhibited (INH) state to the active
(ACT) state, the endpoint menu will be
displayed and it is possible to utilize the
endpoints for this given condition.
*When the function is set ON/OFF at the governor setup
screen, the governor rpm setting channel end point servo
travel and limit point are now initialized.
*When changed from INH to ACT (ON), the servo travel is
initialized to 100 and the limit point is initialized to 155.
*When operation is changed to INH at all conditions, the
servo travel is initialized to 100 and the limit point is
initialized to 135.
184
<Functions of Model Menu (Helicopter Functions)>
*When using an independent governor [ON]/[OFF] switch,
connect the AUX([ON]/[OFF]) connector of the governor to
CH8 and set the switch to CH8 (Governor2) at the Function
menu of the Linkage Menu.
Note: Always set (Control) and (Trim) to [--]
for [Governor] of the Function menu of the
Linkage menu.
(Currently selected condition name)
●Fine tuning VR settings
●RPM adjustment
 Use the Push Dial to scroll to either YES
(incorporate the default endpoints) or NO
(endpoints are not utilized. Push the Return
(RTN) button to confirm the selection made.
●RPM adjustment
Move the cursor to the rate item and push
the RTN button to switch to the data input
mode.
Adjust the rpm by scrolling the Push dial.
Initial value: 50% (1500rpm)
A d j u s t m e n t r a n g e : O F F , 0 ~ 1 1 0 % ( O F F ,
700~3500rpm)
*When the RTN button is pushed for one second, the
sensitivity is reset to the initial value.)
Push the RTN button to return to the cursor
mode.
●Unit diplay selection
Move the cursor to the UNIT item and push
the RTN button to switch to the data input
mode. Select the unit by scrolling the Push
dial.
Push the RTN button to change the operation
mode and return to the cursor mode.
●ACT/INH: INH (initial setting)
<Push Dial>
Scrolling
● Moving cursor
● Selecting mode
● Adjusting value
● To input data mode
● Data is entered