Create MyConfig - Topo
6.8 Axis-drive assignment
machine data
The following machine data that are listed are automatically set by the CMC package within
the course of the axis-drive assignment.
Figure 6-20
Machine data - axis-drive assignment
Machine data, which are not set by the CMC package and which users must supply with the
correct values using a manipulation task, include at least these machine data:
● N20070 $MC_AXCONF_MACHAX_USED
● N20080 $MC_AXCONF_CHANAX_NAME_TAB
6.8.3
Diagnostics
Display: Diagnostics
If you import an NC/DRC archive via the Project > Display/import topology... menu, the topology
will be shown on a gray background.
When you open the "Axis-drive assignment" dialog box, you see the "Display: Diagnosis". This
contains all consistent information required to represent the exact assignment of the relevant
machine data as they have been set on the machine by automatic axis-drive assignment or
manually.
This table is used for diagnostics and checking the axis-drive assignment. If, with the "Import"
button, you take over the topology on a gray background into the topology list of Topo, you
can perform another configuration and the displayed list under "Diagnostics" becomes invalid.
398
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 11/2016, A5E36537479B-AD