Create MyConfig - Expert
4.6 Script language
4.6.11.2

Error

Error ("<label>")
Message output that must be confirmed with OK and results in termination of the package.
Any message text which is also written in the logbook stands for the argument
("<label>") .
4.6.11.3

Warning

Warning ("<label>")
Message output and prompt for cancellation of the package.
Any message text which is also written in the logbook stands for the argument
("<label>") .
4.6.11.4

Log

Log ("<label>")
Logbook entry
Any message text which is only written in the logbook stands for the argument
("<label>").
4.6.11.5

Logging

Logging (<switch>)
Logging in the logbook can be deactivated and reactivated.
For the argument <switch>, the value On can be used for activating and the value Off for
deactivating.
Note
The logging is automatically reset to On at the end of the script (dialog/step script/task).
280