Operation Panel Parameter - Toshiba TOSVERT VF-nC3 Instruction Manual

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-nC3:
Table of Contents

Advertisement

6.18 Operation panel parameter

6.18.1 Prohibition of key operations and parameter settings
 : Parameter write protection selection
 : Panel frequency setting prohibition (FC)
 : Local / remote operation prohibition for remote keypad
 : Panel operation prohibition (RUN/STOP keys)
 : Prohibition of panel emergency stop operation
 : Prohibition of panel reset operation
 : / change prohibition during operation
 : Password setting ()
 : Password examination
• Function
These parameters allow you to prohibit or allow operation of the RUN and STOP keys on the
operation panel and the change of parameters. Using these parameters, you can also prohibit
various key operations. Lock parameters with a password to prevent configuration.
[Parameter setting]
Title

Parameter write protection selection
Panel frequency setting prohibition

(FC)
Local / remote operation prohibition for

remote keypad
Panel operation prohibition

(RUN/STOP keys)
Prohibition of panel emergency stop

operation
 Prohibition of panel reset operation
 /  change prohibition

during operation
 Password setting (  )
 Password examination
Function
0: Permitted
1: Panel and extension panel
prohibited
2: 1 or RS485 communication
prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: No password set
1-9998
9999: Password set
0: No password set
1-9998
9999: Password set
F-57
Adjustment range
Default setting
E6581595
6
0
0
1
0
0
0
1
0
0