• Torque boost parameters 1
Communication
Title
Function
No.
0400
Auto-tuning
0401
Slip frequency
gain
0402
Automatic torque
boost value
0405
Motor rated
capacity
0412
Motor specific
coefficient 1
0415
Motor rated
current
0416
Motor no-load
current
0417
Rated motor
speed
0458
Motor specific
coefficient 2
0459
Load inertia
moment ratio
0460
Motor specific
coefficient 3
0461
Motor specific
coefficient 4
0462
Motor specific
coefficient 5
0467
Motor specific
coefficient 6
• Input/output parameters 2
Communication
Title
Function
No.
0470
VI input bias
0471
VI input gain
• Torque boost parameters 2
Communications
Title
Function
No.
0480
Motor specific
coefficient 7
0485
Motor specific
coefficient 8
0495
Motor specific
coefficient 9
*1: Parameter values vary depending on the capacity. See 11.4.
*2: Depends upon the setup menu settings. See 11.5.
*3: Motor specific coefficient 1 to 9 are parameters exclusively for manufacturer settings. Do not change these parameter.
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
-
-
0: Auto-tuning disabled
1: Initialization of (reset to 0)
2: Auto-tuning executed
(after execution: 0)
%
1/1
0-150
%
0.1/0.1
0.0-30.0
kW
0.01/0.01
0.01-5.50
-
-
-
A
0.1/0.1
0.1-30.0
%
1/1
10-90
min-1
1/1
100-32000
-
-
-
Times
0.1/0.1
0.1-100.0
-
-
-
-
-
-
-
-
-
-
-
-
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
-
1/1
0-255
-
1/1
0-255
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ications
-
-
-
-
-
-
-
-
-
K-9
E6581595
Default
User
Reference
setting
setting
0
6.14
50
* 1
* 1
-
* 3
* 1
6.14
* 1
* 2
-
* 3
1.0
6.14
-
* 3
-
-
-
Default
User
Reference
setting
setting
128
6.5.4
128
Default
User
Reference
setting
setting
-
* 3
-
-
11